Beispiel #1
0
 public static void PopulatePowerSystemResourceProperties(FTN.PowerSystemResource cimPowerSystemResource, ResourceDescription rd)
 {
     if ((cimPowerSystemResource != null) && (rd != null))
     {
         IES1Converter.PopulateIdentifiedObjectProperties(cimPowerSystemResource, rd);
     }
 }
Beispiel #2
0
 public static void PopulateDayTypeProperties(DayType dt, ResourceDescription rd)
 {
     if ((dt != null) && (rd != null))
     {
         IES1Converter.PopulateIdentifiedObjectProperties(dt, rd);
     }
 }
Beispiel #3
0
        public static void PopulateBasicIntervalScheduleProperties(FTN.BasicIntervalSchedule cimBasicIntervalSchedule, ResourceDescription rd)
        {
            if ((cimBasicIntervalSchedule != null) && rd != null)
            {
                IES1Converter.PopulateIdentifiedObjectProperties(cimBasicIntervalSchedule, rd);

                if (cimBasicIntervalSchedule.StartTimeHasValue)
                {
                    rd.AddProperty(new Property(ModelCode.BASIC_INT_SCHED_STARTTIME, cimBasicIntervalSchedule.StartTime));
                }
                if (cimBasicIntervalSchedule.Value1MultiplierHasValue)
                {
                    rd.AddProperty(new Property(ModelCode.BASIC_INT_SCHED_VAL1MUL, (short)GetUnitMultiplier(cimBasicIntervalSchedule.Value1Multiplier)));
                }
                if (cimBasicIntervalSchedule.Value1UnitHasValue)
                {
                    rd.AddProperty(new Property(ModelCode.BASIC_INT_SCHED_VAL1UNIT, (short)GetUnitSymbol(cimBasicIntervalSchedule.Value1Unit)));
                }
                if (cimBasicIntervalSchedule.Value2MultiplierHasValue)
                {
                    rd.AddProperty(new Property(ModelCode.BASIC_INT_SCHED_VAL2MUL, (short)GetUnitMultiplier(cimBasicIntervalSchedule.Value2Multiplier)));
                }
                if (cimBasicIntervalSchedule.Value2UnitHasValue)
                {
                    rd.AddProperty(new Property(ModelCode.BASIC_INT_SCHED_VAL2UNIT, (short)GetUnitSymbol(cimBasicIntervalSchedule.Value2Unit)));
                }
            }
        }
Beispiel #4
0
        public static void PopulateTerminalProperties(Terminal t, ResourceDescription rd, ImportHelper importHelper, TransformAndLoadReport report)
        {
            if ((t != null) && (rd) != null)
            {
                IES1Converter.PopulateIdentifiedObjectProperties(t, rd);

                if (t.ConductingEquipmentHasValue)
                {
                    long gid = importHelper.GetMappedGID(t.ConductingEquipment.ID);

                    if (gid < 0)
                    {
                        report.Report.Append("WARNING: Convert ").Append(t.GetType().ToString()).Append(" rdfID = \"").Append(t.ID);
                        report.Report.Append("\" - Failed to set reference to ConductingEquipment: rdfID \"").Append(t.ConductingEquipment.ID).AppendLine(" \" is not mapped to GID!");
                    }

                    rd.AddProperty(new Property(ModelCode.TERMINAL_CONDEQ, gid));
                }
            }
        }