Beispiel #1
0
        /// <summary>
        /// inserts new record
        /// </summary>
        /// <param name="sender"></param>
        /// <param name="e"></param>
        private void Ok_btn_Click(object sender, EventArgs e)
        {
            InspectionSpecificationVo inVo = new InspectionSpecificationVo();
            var sch = StringCheckHelper.GetInstance();

            if (!CheckMandatory())
            {
                return;
            }

            inVo.InspectionSpecificationText = InspectionSpecificationText_txt.Text.Trim();

            if (InspectionItemDataType == Convert.ToInt32(GlobalMasterDataTypeEnum.DATATYPE_DATETIME.GetValue()) && DateTime_pnl.Visible)
            {
                inVo.ValueFrom = DateFrom_dtp.Value.ToString();
                if (!string.IsNullOrEmpty(DateTo_dtp.Text.Trim()))
                {
                    inVo.ValueTo = DateTo_dtp.Value.ToString();
                }
            }
            else
            {
                inVo.ValueFrom = ValueFrom_txt.Text;
                if (!string.IsNullOrWhiteSpace(ValueTo_txt.Text.Trim()))
                {
                    inVo.ValueTo = ValueTo_txt.Text;
                }
            }

            inVo.Unit = Unit_txt.Text.Trim();

            if (Operator_cmb.SelectedIndex > -1)
            {
                inVo.OperatorFrom = Operator_cmb.SelectedValue.ToString();
            }
            if (!string.IsNullOrWhiteSpace(OperatorTo_txt.Text.Trim()))
            {
                inVo.OperatorTo = GlobalMasterDataTypeEnum.OPERATOR_LESSTHAN.GetValue();
            }

            //inVo.InspectionItemId = Convert.ToInt32(InspectionItem_cmb.SelectedValue.ToString());

            inVo.InspectionItemId = InspectionItemId;

            inVo.SpecificationResultJudgeType = Convert.ToInt32(SpecificationResultJudgeType_cmb.SelectedValue.ToString());

            if (mode.Equals(CommonConstants.MODE_UPDATE))
            {
                inVo.InspectionSpecificationId = inspectionspecificationid;
            }

            inVo.Mode = mode;

            //InspectionSpecificationVo checkVo = DuplicateCheck(inVo);
            //if (checkVo != null && checkVo.AffectedCount > 0)
            //{
            //    messageData = new MessageData("mmce00001", Properties.Resources.mmce00001, InspectionSpecificationCode_lbl.Text + " : " + InspectionSpecificationCode_txt.Text +
            //                                                        Environment.NewLine + " OR " + Environment.NewLine + InspectionItem_lbl.Text + " : " + InspectionItem_cmb.Text);
            //    logger.Info(messageData);
            //    popUpMessage.ConfirmationOkCancel(messageData, Text);

            //    return;
            //}


            if (string.Equals(mode, CommonConstants.MODE_ADD) || string.Equals(mode, CommonConstants.MODE_SELECT))
            {
                inVo.InspectionSpecificationCode = InspectionItemCode + GlobalMasterDataTypeEnum.CODE_SEPARATOR.GetValue() + GlobalMasterDataTypeEnum.SPECIFICATION_CODE.GetValue();

                UpdateResultVo outVo = null;
                try
                {
                    outVo = (UpdateResultVo)base.InvokeCbm(new AddInspectionSpecificationMasterMntCbm(), inVo, false);
                }
                catch (Framework.ApplicationException exception)
                {
                    popUpMessage.ApplicationError(exception.GetMessageData(), Text);
                    logger.Error(exception.GetMessageData());
                    return;
                }
                if (outVo == null)
                {
                    return;
                }
                IntSuccess = outVo.AffectedCount;
            }
            else if (mode.Equals(CommonConstants.MODE_UPDATE))
            {
                inVo.InspectionSpecificationCode = InspectionSpecificationCode;

                //InspectionSpecificationVo outVo = (InspectionSpecificationVo)base.InvokeCbm(new UpdateInspectionSpecificationMasterMntCbm(), inVo, false);


                string message = string.Format(Properties.Resources.mmci00037, "Inspection Specification", InspectionSpecificationText_txt.Text);
                StartProgress(message);

                ValueObjectList <ValueObject> inVoList     = new ValueObjectList <ValueObject>();
                InspectionFormatVo            passformatVo = FormFormatVo(inVo.InspectionItemId);
                if (passformatVo == null || passformatVo.InspectionFormatId == 0)
                {
                    return;
                }

                inVoList.add(passformatVo);
                inVoList.add(null);
                inVoList.add(null);
                inVoList.add(null);
                inVoList.add(inVo);
                inVoList.add(null);
                inVoList.add(null);

                InspectionReturnVo outVo = null;
                try
                {
                    outVo = (InspectionReturnVo)base.InvokeCbm(new UpdateAllInspectionFunctionMasterMntCbm(), inVoList, false);
                }
                catch (Framework.ApplicationException exception)
                {
                    popUpMessage.ApplicationError(exception.GetMessageData(), Text);
                    logger.Error(exception.GetMessageData());
                    return;
                }
                finally
                {
                    CompleteProgress();
                }
                if (outVo != null && outVo.AffectedCount > 0)
                {
                    IntSuccess       = outVo.AffectedCount;
                    InspectionItemId = outVo.InspectionItemId;
                }
            }
            if ((IntSuccess > 0))
            {
                messageData = new MessageData("mmci00001", Properties.Resources.mmci00001, null);
                logger.Info(messageData);
                popUpMessage.Information(messageData, Text);
                this.Close();
            }
        }
Beispiel #2
0
        public ValueObject Execute(TransactionContext trxContext, ValueObject vo)
        {
            ValueObjectList <ValueObjectList <ValueObject> > inVo = (ValueObjectList <ValueObjectList <ValueObject> >)vo;

            if (inVo == null || inVo.GetList() == null || inVo.GetList().Count == 0)
            {
                return(outVo);
            }

            ValueObjectList <ValueObject> updateSpecificationListVo = new ValueObjectList <ValueObject>();
            UpdateResultVo returnitemSpecificationInsertedVo        = null;

            updateSpecificationListVo = inVo.GetList()[inVo.GetList().Count - 1];
            if (updateSpecificationListVo != null && updateSpecificationListVo.GetList() != null && updateSpecificationListVo.GetList().Count > 0)
            {
                UpdateSpecificationVo = new InspectionSpecificationVo();
                UpdateSpecificationVo = (InspectionSpecificationVo)updateSpecificationListVo.GetList()[0];
            }

            inVo.GetList().RemoveAt(inVo.GetList().Count - 1);

            //get inspection Specification list for the above fetched itemlist
            InspectionSpecificationListInVo = (ValueObjectList <InspectionSpecificationVo>)getInspectionSpecficationListCbm.Execute(trxContext, inVo);
            if (InspectionSpecificationListInVo == null || InspectionSpecificationListInVo.GetList() == null || InspectionSpecificationListInVo.GetList().Count == 0)
            {
                return(outVo);
            }

            if (UpdateSpecificationVo != null && UpdateSpecificationVo.InspectionSpecificationId > 0)
            {
                if (UpdateSpecificationVo.DeleteFlag)
                {
                    InspectionSpecificationListInVo.GetList().Remove(InspectionSpecificationListInVo.GetList().Single(v => v.InspectionSpecificationId == UpdateSpecificationVo.InspectionSpecificationId));
                }
                else
                {
                    foreach (InspectionSpecificationVo ItemVo in InspectionSpecificationListInVo.GetList().Where(v => v.InspectionSpecificationId == UpdateSpecificationVo.InspectionSpecificationId))
                    {
                        ItemVo.InspectionSpecificationCode = UpdateSpecificationVo.InspectionSpecificationCode;
                        ItemVo.InspectionSpecificationText = UpdateSpecificationVo.InspectionSpecificationText;
                        ItemVo.ValueFrom                    = UpdateSpecificationVo.ValueFrom;
                        ItemVo.ValueTo                      = UpdateSpecificationVo.ValueTo;
                        ItemVo.Unit                         = UpdateSpecificationVo.Unit;
                        ItemVo.OperatorFrom                 = UpdateSpecificationVo.OperatorFrom;
                        ItemVo.OperatorTo                   = UpdateSpecificationVo.OperatorTo;
                        ItemVo.InspectionItemId             = UpdateSpecificationVo.InspectionItemId;
                        ItemVo.SpecificationResultJudgeType = UpdateSpecificationVo.SpecificationResultJudgeType;
                    }
                }
            }


            foreach (ValueObjectList <ValueObject> getitemVo in inVo.GetList())
            {
                InspectionItemVo OldInsProcessVo = (InspectionItemVo)getitemVo.GetList()[0];
                InspectionItemVo NewInsProcessVo = (InspectionItemVo)getitemVo.GetList()[1];

                foreach (InspectionSpecificationVo inspectionSpecificationVo in InspectionSpecificationListInVo.GetList().Where(v => v.InspectionItemId == OldInsProcessVo.InspectionItemId).Distinct())
                {
                    inspectionSpecificationVo.InspectionItemId            = NewInsProcessVo.InspectionItemId;
                    inspectionSpecificationVo.InspectionSpecificationCode = NewInsProcessVo.InspectionItemCode +
                                                                            GlobalMasterDataTypeEnum.CODE_SEPARATOR.GetValue() +
                                                                            GlobalMasterDataTypeEnum.SPECIFICATION_CODE.GetValue();
                }

                if (UpdateSpecificationVo != null)
                {
                    if (UpdateSpecificationVo.InspectionItemId == OldInsProcessVo.InspectionItemId)
                    {
                        UpdateSpecificationVo.InspectionItemId = NewInsProcessVo.InspectionItemId;
                    }
                }
            }

            returnitemSpecificationInsertedVo = (UpdateResultVo)addInspectionSpecificationCopyCbm.Execute(trxContext, InspectionSpecificationListInVo);

            if (UpdateSpecificationVo != null)
            {
                if (outVo == null)
                {
                    outVo = new InspectionReturnVo();
                }
                outVo.InspectionItemId = UpdateSpecificationVo.InspectionItemId;
            }

            return(outVo);
        }
        public override ValueObject Execute(TransactionContext trxContext, ValueObject arg)
        {
            ValueObjectList <ValueObjectList <ValueObject> > inVo = (ValueObjectList <ValueObjectList <ValueObject> >)arg;
            List <int> ItemList = new List <int>();

            foreach (ValueObjectList <ValueObject> getItemVo in inVo.GetList())
            {
                if ((((InspectionItemVo)getItemVo.GetList()[0]).InspectionItemId) != 0)
                {
                    ItemList.Add(((InspectionItemVo)getItemVo.GetList()[0]).InspectionItemId);
                }
            }

            StringBuilder sqlQuery = new StringBuilder();

            sqlQuery.Append("select * ");
            sqlQuery.Append(" from m_inspection_specification");
            sqlQuery.Append(" where factory_cd = :faccd ");
            sqlQuery.Append(" and inspection_item_id = ANY (:inspectionItemId) ");

            sqlQuery.Append(" order by inspection_specification_id ");

            //create command
            DbCommandAdaptor sqlCommandAdapter = base.GetDbCommandAdaptor(trxContext, sqlQuery.ToString());

            //create parameter
            DbParameterList sqlParameter = sqlCommandAdapter.CreateParameterList();

            sqlParameter.AddParameterString("faccd", UserData.GetUserData().FactoryCode);
            sqlParameter.AddParameter("inspectionItemId", ItemList);

            //execute SQL
            IDataReader dataReader = sqlCommandAdapter.ExecuteReader(trxContext, sqlParameter);

            ValueObjectList <InspectionSpecificationVo> outVo = null;

            while (dataReader.Read())
            {
                InspectionSpecificationVo currOutVo = new InspectionSpecificationVo();

                currOutVo.InspectionSpecificationId   = ConvertDBNull <int>(dataReader, "inspection_specification_id");
                currOutVo.InspectionSpecificationCode = ConvertDBNull <string>(dataReader, "inspection_specification_cd");
                currOutVo.InspectionSpecificationText = ConvertDBNull <string>(dataReader, "inspection_specification_text");
                currOutVo.ValueFrom                    = ConvertDBNull <string>(dataReader, "value_from");
                currOutVo.ValueTo                      = ConvertDBNull <string>(dataReader, "value_to");
                currOutVo.Unit                         = ConvertDBNull <string>(dataReader, "unit");
                currOutVo.OperatorFrom                 = ConvertDBNull <string>(dataReader, "operator_from");
                currOutVo.OperatorTo                   = ConvertDBNull <string>(dataReader, "operator_to");
                currOutVo.InspectionItemId             = ConvertDBNull <int>(dataReader, "inspection_item_id");
                currOutVo.SpecificationResultJudgeType = ConvertDBNull <int>(dataReader, "specification_result_judge_type");

                if (outVo == null)
                {
                    outVo = new ValueObjectList <InspectionSpecificationVo>();
                }
                outVo.add(currOutVo);
            }
            dataReader.Close();

            return(outVo);
        }
Beispiel #4
0
        /// <summary>
        /// inserts new record
        /// </summary>
        /// <param name="sender"></param>
        /// <param name="e"></param>
        private void Ok_btn_Click(object sender, EventArgs e)
        {
            InspectionSpecificationVo inVo = new InspectionSpecificationVo();
            var sch = StringCheckHelper.GetInstance();

            if (CheckMandatory() == true)
            {
                if (string.IsNullOrEmpty(InspectionSpecificationCode_txt.Text) || string.IsNullOrEmpty(InspectionSpecificationText_txt.Text))
                {
                    messageData = new MessageData("mmce00003", Properties.Resources.mmce00003);
                    logger.Info(messageData);
                    popUpMessage.ConfirmationOkCancel(messageData, Text);

                    if (string.IsNullOrEmpty(InspectionSpecificationCode_txt.Text))
                    {
                        InspectionSpecificationCode_txt.Focus();
                    }
                    else if (string.IsNullOrEmpty(InspectionSpecificationText_txt.Text))
                    {
                        InspectionSpecificationText_txt.Focus();
                    }
                    return;
                }

                if (string.Equals(mode, CommonConstants.MODE_SELECT))
                {
                    if (InspectionSpecificationCode_txt.Text == updateData.InspectionSpecificationCode)
                    {
                        messageData = new MessageData("mmce00001", Properties.Resources.mmce00001, InspectionSpecificationCode_lbl.Text + " : " + InspectionSpecificationCode_txt.Text);
                        logger.Info(messageData);
                        popUpMessage.ConfirmationOkCancel(messageData, Text);

                        return;
                    }
                    if (InspectionSpecificationText_txt.Text == updateData.InspectionSpecificationText)
                    {
                        messageData = new MessageData("mmce00001", Properties.Resources.mmce00001, InspectionSpecificationText_lbl.Text + " : " + InspectionSpecificationText_txt.Text);
                        logger.Info(messageData);
                        popUpMessage.ConfirmationOkCancel(messageData, Text);

                        return;
                    }
                }

                inVo.InspectionSpecificationCode = InspectionSpecificationCode_txt.Text.Trim();

                inVo.InspectionSpecificationText = InspectionSpecificationText_txt.Text.Trim();

                // inVo.ValueFrom = Convert.ToDecimal(ValueFrom_txt.Text.Trim());

                if (!string.IsNullOrWhiteSpace(ValueTo_txt.Text.Trim()))
                {
                    //  inVo.ValueTo = Convert.ToDecimal(ValueTo_txt.Text.Trim());
                }

                if (!string.IsNullOrWhiteSpace(Unit_txt.Text.Trim()))
                {
                    inVo.Unit = Unit_txt.Text.Trim();
                }

                if (!string.IsNullOrWhiteSpace(OperatorFrom_txt.Text.Trim()))
                {
                    inVo.OperatorFrom = OperatorFrom_txt.Text.Trim();
                }

                if (!string.IsNullOrWhiteSpace(OperatorTo_txt.Text.Trim()))
                {
                    inVo.OperatorTo = OperatorTo_txt.Text.Trim();
                }

                inVo.InspectionItemId = Convert.ToInt32(InspectionItem_cmb.SelectedValue.ToString());

                inVo.SpecificationResultJudgeType = Convert.ToInt32(SpecificationResultJudgeType_cmb.SelectedValue.ToString());

                if (mode.Equals(CommonConstants.MODE_UPDATE))
                {
                    inVo.InspectionSpecificationId = updateData.InspectionSpecificationId;
                }

                inVo.Mode = mode;

                InspectionSpecificationVo checkVo = DuplicateCheck(inVo);

                if (checkVo != null && checkVo.AffectedCount > 0)
                {
                    messageData = new MessageData("mmce00001", Properties.Resources.mmce00001, InspectionSpecificationCode_lbl.Text + " : " + InspectionSpecificationCode_txt.Text +
                                                  Environment.NewLine + " OR " + Environment.NewLine + InspectionItem_lbl.Text + " : " + InspectionItem_cmb.Text);
                    logger.Info(messageData);
                    popUpMessage.ConfirmationOkCancel(messageData, Text);

                    return;
                }

                try
                {
                    if (string.Equals(mode, CommonConstants.MODE_ADD) || string.Equals(mode, CommonConstants.MODE_SELECT))
                    {
                        UpdateResultVo outVo = (UpdateResultVo)base.InvokeCbm(new AddInspectionSpecificationMasterMntCbm(), inVo, false);

                        IntSuccess = outVo.AffectedCount;
                    }
                    else if (mode.Equals(CommonConstants.MODE_UPDATE))
                    {
                        InspectionSpecificationVo outVo = (InspectionSpecificationVo)base.InvokeCbm(new UpdateInspectionSpecificationMasterMntCbm(), inVo, false);

                        IntSuccess = outVo.AffectedCount;
                    }
                }
                catch (Framework.ApplicationException exception)
                {
                    popUpMessage.ApplicationError(exception.GetMessageData(), Text);
                    logger.Error(exception.GetMessageData());
                    return;
                }

                if ((IntSuccess > 0) || (IntSuccess == 0))
                {
                    this.Close();
                }
            }
        }