private void btnOnOff_CheckedChanged(object sender, EventArgs e) { if (btnOnOff.Checked == true) { m_hmp = new HMP4040(AppSettings.Instance.Config.visaName); if (m_hmp.Initialize(out string idQueryResponse, out string outMessage) == false) { MessageBox.Show("Initialize failed: " + outMessage); } else { this.Text = "HMP4040 - Connected"; hmP4040Channel1.Enabled = true; hmP4040Channel2.Enabled = true; hmP4040Channel3.Enabled = true; hmP4040Channel4.Enabled = true; hmP4040Channel1.Connected(m_hmp); hmP4040Channel2.Connected(m_hmp); hmP4040Channel3.Connected(m_hmp); hmP4040Channel4.Connected(m_hmp); m_connected = true; m_hmpReadThread = new Thread(HMPReader); m_hmpReadThread.Start(); } }
public void Connected(HMP4040 hmp) { try { if (m_hmp != null && hmp == null) { m_hmp.SetOutputEnable(m_outputChannel, false); tsOutputEnable.Checked = false; } if (hmp != null) { hmp.GetOutputEnable(m_outputChannel, out bool enable); tsOutputEnable.Checked = enable; lbOnOff.On = enable; double value; hmp.GetOutputVoltageLevel(m_outputChannel, out value); txtOutputVoltageLevel.Text = value.ToString(); ssVoltage.Text = value.ToString(); hmp.GetOverVoltageProtectionLevel(m_outputChannel, out value); txtOverProtectionLevel.Text = value.ToString(); hmp.GetOutputCurrentLevel(m_outputChannel, out value); txtOutputCurrentLevel.Text = value.ToString(); } m_hmp = hmp; } catch (Exception err) { MessageBox.Show(err.Message); } }