/// <summary> /// insert new row in the table /// </summary> /// <param name="businessObject">business object</param> /// <returns>true of successfully insert</returns> public bool Insert(CElement_wavelength businessObject) { NpgsqlCommand sqlCommand = new NpgsqlCommand(); sqlCommand.CommandText = "public.sp_element_wavelength_Insert"; sqlCommand.CommandType = CommandType.StoredProcedure; // Use connection object of base class sqlCommand.Connection = MainConnection; try { sqlCommand.Parameters.AddWithValue("p_idelement_wavelength", businessObject.Idelement_wavelength); sqlCommand.Parameters["p_idelement_wavelength"].NpgsqlDbType = NpgsqlDbType.Integer; sqlCommand.Parameters["p_idelement_wavelength"].Direction = ParameterDirection.InputOutput; sqlCommand.Parameters.AddWithValue("p_idelement", businessObject.Idelement); sqlCommand.Parameters["p_idelement"].NpgsqlDbType = NpgsqlDbType.Smallint; sqlCommand.Parameters.AddWithValue("p_wavelength", businessObject.Wavelength); sqlCommand.Parameters["p_wavelength"].NpgsqlDbType = NpgsqlDbType.Varchar; sqlCommand.Parameters.AddWithValue("p_element_wavelength", businessObject.Element_wavelength); sqlCommand.Parameters["p_element_wavelength"].NpgsqlDbType = NpgsqlDbType.Varchar; sqlCommand.Parameters.AddWithValue("p_idl_axial", businessObject.Idl_axial); sqlCommand.Parameters["p_idl_axial"].NpgsqlDbType = NpgsqlDbType.Numeric; sqlCommand.Parameters.AddWithValue("p_idl_radial", businessObject.Idl_radial); sqlCommand.Parameters["p_idl_radial"].NpgsqlDbType = NpgsqlDbType.Numeric; sqlCommand.Parameters.AddWithValue("p_lineality_axial", businessObject.Lineality_axial); sqlCommand.Parameters["p_lineality_axial"].NpgsqlDbType = NpgsqlDbType.Numeric; sqlCommand.Parameters.AddWithValue("p_lineality_radial", businessObject.Lineality_radial); sqlCommand.Parameters["p_lineality_radial"].NpgsqlDbType = NpgsqlDbType.Numeric; sqlCommand.Parameters.AddWithValue("p_usernew", businessObject.Usernew); sqlCommand.Parameters["p_usernew"].NpgsqlDbType = NpgsqlDbType.Varchar; sqlCommand.Parameters.AddWithValue("p_datenew", businessObject.Datenew); sqlCommand.Parameters["p_datenew"].NpgsqlDbType = NpgsqlDbType.Timestamp; sqlCommand.Parameters.AddWithValue("p_useredit", businessObject.Useredit); sqlCommand.Parameters["p_useredit"].NpgsqlDbType = NpgsqlDbType.Varchar; sqlCommand.Parameters.AddWithValue("p_dateedit", businessObject.Dateedit); sqlCommand.Parameters["p_dateedit"].NpgsqlDbType = NpgsqlDbType.Timestamp; sqlCommand.Parameters.AddWithValue("p_status", businessObject.Status); sqlCommand.Parameters["p_status"].NpgsqlDbType = NpgsqlDbType.Boolean; MainConnection.Open(); sqlCommand.ExecuteNonQuery(); businessObject.Idelement_wavelength = Convert.ToInt32(sqlCommand.Parameters["p_idelement_wavelength"].Value); return(true); } catch (Exception ex) { throw new Exception("CElement_wavelength::Insert::Error occured.", ex); } finally { MainConnection.Close(); sqlCommand.Dispose(); } }
/// <summary> /// Populate business objects from the data reader /// </summary> /// <param name="dataReader">data reader</param> /// <returns>list of CElement_wavelength</returns> internal List <CElement_wavelength> PopulateObjectsFromReader(IDataReader dataReader) { List <CElement_wavelength> list = new List <CElement_wavelength>(); while (dataReader.Read()) { CElement_wavelength businessObject = new CElement_wavelength(); PopulateBusinessObjectFromReader(businessObject, dataReader); list.Add(businessObject); } return(list); }
/// <summary> /// Select by primary key /// </summary> /// <param name="keys">primary keys</param> /// <returns>CElement_wavelength business object</returns> public CElement_wavelength SelectByPrimaryKey(CElement_wavelengthKeys keys) { NpgsqlCommand sqlCommand = new NpgsqlCommand(); sqlCommand.CommandText = "public.sp_element_wavelength_SelectByPrimaryKey"; sqlCommand.CommandType = CommandType.StoredProcedure; // Use connection object of base class sqlCommand.Connection = MainConnection; try { sqlCommand.Parameters.Add(new NpgsqlParameter("p_idelement_wavelength", NpgsqlDbType.Integer, 4, "", ParameterDirection.Input, false, 0, 0, DataRowVersion.Proposed, keys.Idelement_wavelength)); MainConnection.Open(); NpgsqlDataReader dataReader = sqlCommand.ExecuteReader(); if (dataReader.Read()) { CElement_wavelength businessObject = new CElement_wavelength(); PopulateBusinessObjectFromReader(businessObject, dataReader); return(businessObject); } else { return(null); } } catch (Exception ex) { throw new Exception("CElement_wavelength::SelectByPrimaryKey::Error occured.", ex); } finally { MainConnection.Close(); sqlCommand.Dispose(); } }
/// <summary> /// Populate business object from data reader /// </summary> /// <param name="businessObject">business object</param> /// <param name="dataReader">data reader</param> internal void PopulateBusinessObjectFromReader(CElement_wavelength businessObject, IDataReader dataReader) { businessObject.Idelement_wavelength = dataReader.GetInt32(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Idelement_wavelength.ToString())); if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Idelement.ToString()))) { businessObject.Idelement = (short?)dataReader.GetInt16(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Idelement.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Wavelength.ToString()))) { businessObject.Wavelength = dataReader.GetString(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Wavelength.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Element_wavelength.ToString()))) { businessObject.Element_wavelength = dataReader.GetString(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Element_wavelength.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Idl_axial.ToString()))) { businessObject.Idl_axial = dataReader.GetDecimal(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Idl_axial.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Idl_radial.ToString()))) { businessObject.Idl_radial = dataReader.GetDecimal(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Idl_radial.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Lineality_axial.ToString()))) { businessObject.Lineality_axial = dataReader.GetDecimal(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Lineality_axial.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Lineality_radial.ToString()))) { businessObject.Lineality_radial = dataReader.GetDecimal(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Lineality_radial.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Usernew.ToString()))) { businessObject.Usernew = dataReader.GetString(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Usernew.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Datenew.ToString()))) { businessObject.Datenew = dataReader.GetDateTime(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Datenew.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Useredit.ToString()))) { businessObject.Useredit = dataReader.GetString(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Useredit.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Dateedit.ToString()))) { businessObject.Dateedit = dataReader.GetDateTime(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Dateedit.ToString())); } if (!dataReader.IsDBNull(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Status.ToString()))) { businessObject.Status = dataReader.GetBoolean(dataReader.GetOrdinal(CElement_wavelength.CElement_wavelengthFields.Status.ToString())); } }