OPC UA Publisher Module for the Azure IoT Gateway SDK

This reference implementation demonstrates how the Azure IoT Gateway SDK can be used to connect to existing OPC UA servers and send JSON encoded telemetry data from these servers in OPC UA "Pub/Sub" format (using a JSON payload) to Azure IoT Hub. All transport protocols supported by the Gateway SDK can be used, i.e. HTTPS, AMQP and MQTT. The transport is selected in the transport setting in gateway_config.json.

This module uses the OPC Foundations's OPC UA reference stack and therefore licensing restrictions apply. Visit http://opcfoundation.github.io/UA-.NETStandardLibrary/ for OPC UA documentation and licensing terms.

Branch Status
master Build status Build Status

Azure IoT Gateway SDK compatibility

The current version of the Proxy module is targeted at the Azure IoT Gateway SDK at commit '287beed07490d98a24a4e9ddd33ec7127fc3acbf'.

Use the following command line to clone the compatible version Azure IoT Gateway SDK, then follow the build instructions included:

git clone --recursive https://github.com/Azure/azure-iot-gateway-sdk.git
git checkout 287beed07490d98a24a4e9ddd33ec7127fc3acbf

The gateway needs to be build with the --enable-dotnet-core-binding flag to enable it to run this module.

Directory Structure

/samples

This folder contains a sample configuration that instructs a vanilla gateway host load the module and IoT Hub proxy module and configures the module to create a subscription on a standard server which publishes the current server time to Azure IoT Hub.

/src

This folder contains the C# OPC UA module source file (Module.cs).

/bld

This folder contains build scripts for Windows and Linux.

Building the Module

Run bld/build to build the module both Debug and Release. The published module can be found in build/release folder. Run the build script with the --help command line argument to see all build options.

The build system requires the latest .net Core command line tools to be installed (1.1.1 or later). On Windows, install Visual Studio 2017 with the dotnet core work load. On Linux, follow the instructions here.

Configuring the Module

OPC UA nodes whose values should be published to Azure IoT Hub can be configured in the module JSON configuration. A sample template configuration file can be found in samples/gateway_config.json. The configuration consists of a OPC-UA Application Configuration and Subscriptions section.

Application Configuration section

The Configuration Section must contain at a minimum all items shown in the sample template. The JSON type conforms to the OPC UA reference stack serialization of the ApplicationConfiguration type.

E.g. to enable automatic certificate accept (discouraged), set "AutoAcceptUntrustedCertificates" to true (default is false) inside the SecurityConfiguration section:

           "args": {
                "Configuration": {
                    "ApplicationName": "Opc.Ua.Client.SampleModule",
                    "ApplicationType": "Client",
                    "ApplicationUri": "urn:localhost:OPCFoundation:SampleModule",
                    "SecurityConfiguration": {
                        "ApplicationCertificate": {},
                        "AutoAcceptUntrustedCertificates": true
                    },

Subscriptions section

The Subscriptions Section contains an array of OPC-UA sessions that the module should establish at startup, with each specifying a list of items to monitor. The MonitoredItems array type in the JSON configuration conforms to the OPC UA reference stack serialization specification of the same type.

E.g. the sample template shows how to monitor the Current Server Time node (node ID 2258):

                },
                "Subscriptions": [
                    {
                        "Id": "<DeviceID>",
                        "SharedAccessKey": "<SharedAccessKey>",
                        "ServerUrl": "opc.tcp://<hostname>:51210/UA/SampleServer",
						"MinimumSecurityLevel": 0,
						"MinimumSecurityMode": "SignAndEncrypt",
                        "PublishingInterval": 400,
                        "MonitoredItems": [
                            {
                                "StartNodeId": "i=2258",
                                "NodeClass": 2,
                                "DisplayName": "ServerStatusCurrentTime",
                                "DiscardOldest": false
                            }
                        ]
                    }
                ]
            },

The JSON snippet above shows the default security settings, which can thus be ommitted. By default the session is created on the endpoint that supports SignAndEncrypt message mode, regardless of the security level advertised by the server (0). You can adjust these settings to customize the endpoint selection process, e.g. setting the Security mode to "Sign" will select all Sign and SignAndEncrypt endpoints, "None" will select all endpoints.

Running the module

To run the module and have it publish to IoT Hub, configure the name of your Hub (JSON field "IoTHubName") and the IoT Hub device ID and shared access key to use (JSON fields "Id" and "SharedAccessKey") in your version of gateway_config.json. Note that if you use a "Mapping" module in your configuration, you can omit the "SharedAccessKey" field. Finally, ensure that the right native module is configured, based on your platform (i.e. iothub.dll for Windows, libiothub.so for Linux, etc.).

You can build a sample gateway host as part of the Azure IoT Gateway SDK build system. Ensure that you pass the --enable-dotnet-core-binding to the build script and use one of the resulting sample gateway hosts.

To simplify this step, and to build a sample gateway to host the OPC-UA module - along with the module itself - clone the gateway SDK repo to your device and run the build script with the -i <root-of-sdk>. The resulting release folder will contain not just the module and managed dependencies, but also a native IoT Hub proxy module as well as a sample_gateway executable that you can pass the updated JSON configuration to.