SmartModbusMaster

It converts Modbus polling function to event. It uses NModbus

Usage

class Program
{
    static void Main(string[] args)
    {           
        myDevices = Creator.FromFile("addresses.csv");
	if (myDevices == null)
        {
            return;
        }
        myDevices.TagStatusChanged += MyDevices_TagStatusChanged;      
        myDevices.StartDevices();

        Console.ReadLine();
    }
    
    private static void MyDevices_TagStatusChanged(object sender, TagChangedEventArgs e)
    {
        if (e.quality)
        {
             Console.WriteLine(e.Name + ": " + e.Value);
        }
    }
}

CSV File

The CSV file consists of two parts. The first section contains device information. The second section contains address information.

Device section:

Row Type Device Ip Port Device ID Refresh Rate IsActive
device Device1 10.3.4.247 502 1 1000 1
device Device2 10.3.4.248 502 2 2000 1
Column Name Description
Row Type Must be 'device' for device section
Device Device name
Ip IP address to connect
Port Port to connect
Device ID An unique number for device
Refresh Rate Refresh rate in milliseconds
IsActive 1: Active, 0: deactive

Tag section:

Row Type Tag Device Address Modbus Type Direction Type MaskType Mask Merge Type Range
tag TagName1 Device1 1 cs read bool none 0 ormerge 0
tag TagName2 Device1 2 cs read bool none 0 ormerge 0
tag TagName3 Device2 2 cs read bool none 0 ormerge 0
Column Name Description
Row Type Must be 'tag' for tag section
Tag A tag for address
Device Device name written in the device section
Address read address x: only reads x, x y: reads x and y, x-y: reads x to y
Modbus Type cs: Coil Status, is: Input status, hr: holding register, ir: input register
Type bool: boolean, ushort: ushort, lsrf: lsrf float, msrf: msrf float
MaskType none, andmask, ormask
Mask ushort mask value
Merge Type ormerge, andmerge
Range ushort range value

Sample CSV file:

//device,Device,Ip,Port,DeviceId,RefreshRate,IsActive
device,Device1,10.3.4.247,502,1,1000,1
device,Device2,10.3.4.248,502,2,1000,1
//tag,Tag,Device,Address,ModbusType(cs/is/hr/ir),Direction(read/write),Type(bool/ushort/lsrf/msrf),MaskType(none/andmask/ormask),Mask,MergeType(andmerge/ormerge),Range
tag,TagName1,Device1,1,cs,read,bool,none,0,ormerge,0
tag,TagName2,Device1,1,cs,read,bool,none,0,ormerge,0
tag,TagName3,Device2,1,cs,read,bool,none,0,ormerge,0