public Form1() { BlockingCollection <RawData> rawData = new BlockingCollection <RawData>(); DAQ daq = new DAQ(); converter = new ConvertAlgo(); IDAQ transducerdaq = new TransducerDAQ(daq, rawData); dataTreatment = new DataTreatment(rawData, converter); Measure = new UC2M2_UC3M3_Measure(transducerdaq, dataTreatment); InitializeComponent(); dataTreatment.Attach(this); // Lars GUIgraphList = new List <ConvertedData>(); }
static void Main(string[] args) { BlockingCollection <RawData> rawData = new BlockingCollection <RawData>(); DAQ daq = new DAQ(); IDAQ transducerdaq = new TransducerDAQ(daq, rawData); UC2M2_UC3M3_Measure newMeasurement = new UC2M2_UC3M3_Measure(transducerdaq); DataTreatment dataTreatment = new DataTreatment(rawData); newMeasurement.StartMeasurement(); dataTreatment.ShowData(); Console.ReadKey(); }
static void Main(string[] args) { BlockingCollection <RawData> rawCollection = new BlockingCollection <RawData>(); BlockingCollection <RawData> graphCollection = new BlockingCollection <RawData>(); DAQ daq = new DAQ(); ConvertAlgo convertAlgo = new ConvertAlgo(); IDAQ transducerdaq = new TransducerDAQ(daq, rawCollection); DataTreatment dataTreatment = new DataTreatment(rawCollection, graphCollection, convertAlgo, ); IMeasure measurement = new UC2M2_UC3M3_Measure(transducerdaq, dataTreatment); Application.EnableVisualStyles(); Application.SetCompatibleTextRenderingDefault(false); Application.Run(new MainGUI(dataTreatment)); }
static void Main() { BlockingCollection <double> rawCollection = new BlockingCollection <double>(); BlockingCollection <double> graphCollection = new BlockingCollection <double>(); BlockingCollection <double> calibrationCollection = new BlockingCollection <double>(); BlockingCollection <double> alarmCollection = new BlockingCollection <double>(); BlockingCollection <double> filterCollection = new BlockingCollection <double>(); DAQ daq = new DAQ(); ConvertAlgo convertAlgo = new ConvertAlgo(); BloodPressureAlgo bpAlgo = new BloodPressureAlgo(); PulseAlgo pulseAlgo = new PulseAlgo(); IDAQ transducerdaq = new TransducerDAQ(daq, rawCollection, calibrationCollection); IData data = new Database(); IAlarmType alarmType = new HighAlarm(); ILimits limits = new UC9S5_Limits(); IAlarm alarm = new UC5S1_Alarm(alarmCollection, limits, alarmType, bpAlgo); IFilter filter = new UC7S3_Filter(filterCollection, data, convertAlgo); UC1M1_ZeroAdjustment uc1 = new UC1M1_ZeroAdjustment(calibrationCollection, transducerdaq); DataTreatment dataTreatment = new DataTreatment(rawCollection, graphCollection, filterCollection, alarmCollection, convertAlgo, data, alarm, uc1); IMeasure measurement = new UC2M2_UC3M3_Measure(transducerdaq, dataTreatment, alarm, filter); ICalibrate calibrate = new UC6S2_Calibrate(calibrationCollection, transducerdaq, data); IZeroAdjustment zero = new UC1M1_ZeroAdjustment(calibrationCollection, transducerdaq); IPulse pulse = new UC8S4_Pulse(dataTreatment, pulseAlgo); ISave save = new UC4M4_SaveData(data, dataTreatment); Application.EnableVisualStyles(); Application.SetCompatibleTextRenderingDefault(false); ZeroAdjustmentGUI zeroAdjustment = new ZeroAdjustmentGUI(zero); CalibrateGUI calibrateGUI = new CalibrateGUI(calibrate, measurement); LoginToCalibrateGUI login = new LoginToCalibrateGUI(calibrateGUI); SaveDataGUI saveGUI = new SaveDataGUI(save); ChangeLimitsGUI limitsGUI = new ChangeLimitsGUI(limits); MainGUI gui = new MainGUI(dataTreatment, measurement, login, zeroAdjustment, alarm, pulse, bpAlgo, filter, saveGUI, limitsGUI, calibrateGUI); Application.Run(gui); }