Ejemplo n.º 1
0
        public override void Execute(ResultCollection resultList)
        {
            Check.Require(resultList.Run.CurrentMassTag != null, "ChromPeakSelector failed. Mass Tag must be defined but it isn't.");
            Check.Require(resultList.Run.PeakList != null, "ChromPeakSelector failed. Peak list has not been established. You need to run a peak detector.");
            Check.Require(resultList.Run.PeakList.Count > 0, "ChromPeakSelector failed. Peak list is empty.");
            Check.Require(resultList.Run.PeakList[0] is ChromPeak, "ChromPeakSelector failed. Input peaklist contains the wrong type of peak");

            var result = resultList.GetTargetedResult(resultList.Run.CurrentMassTag);


            float normalizedElutionTime;

            if (result.Run.CurrentMassTag.ElutionTimeUnit == DeconTools.Backend.Globals.ElutionTimeUnit.ScanNum)
            {
                normalizedElutionTime = resultList.Run.CurrentMassTag.ScanLCTarget / (float)result.Run.GetNumMSScans();
            }
            else
            {
                normalizedElutionTime = resultList.Run.CurrentMassTag.NormalizedElutionTime;
            }


            var numPeaksWithinTolerance = 0;
            var bestPeak = (ChromPeak)selectBestPeak(Parameters.PeakSelectorMode,
                                                     resultList.Run.PeakList, normalizedElutionTime,
                                                     Parameters.NETTolerance, out numPeaksWithinTolerance);

            result.AddNumChromPeaksWithinTolerance(numPeaksWithinTolerance);

            result.Run.CurrentScanSet = ChromPeakUtilities.GetLCScanSetForChromPeak(bestPeak, resultList.Run, Parameters.NumScansToSum);

            UpdateResultWithChromPeakAndLCScanInfo(result, bestPeak);
        }
        public override void Execute(ResultCollection resultList)
        {
            Check.Require(resultList.Run.CurrentMassTag != null, this.Name + " failed. MassTag was not defined.");

            var currentResult = resultList.GetTargetedResult(resultList.Run.CurrentMassTag);

            if (msgen == null)
            {
                msgen = MSGeneratorFactory.CreateMSGenerator(resultList.Run.MSFileType);
                msgen.IsTICRequested = false;
            }

            var currentTarget = resultList.Run.CurrentMassTag;

            // Set the MS Generator to use a window around the target so that we do not grab a lot of unecessary data from the UIMF file
            msgen.MinMZ = currentTarget.MZ - 10;
            msgen.MaxMZ = currentTarget.MZ + 10;

            float normalizedElutionTime;

            if (currentResult.Run.CurrentMassTag.ElutionTimeUnit == DeconTools.Backend.Globals.ElutionTimeUnit.ScanNum)
            {
                normalizedElutionTime = resultList.Run.CurrentMassTag.ScanLCTarget / (float)currentResult.Run.GetNumMSScans();
            }
            else
            {
                normalizedElutionTime = resultList.Run.CurrentMassTag.NormalizedElutionTime;
            }

            //collect Chrom peaks that fall within the NET tolerance
            var peaksWithinTol = new List <ChromPeak>(); //

            foreach (ChromPeak peak in resultList.Run.PeakList)
            {
                if (Math.Abs(peak.NETValue - normalizedElutionTime) <= Parameters.NETTolerance)     //peak.NETValue was determined by the ChromPeakDetector or a future ChromAligner Task
                {
                    peaksWithinTol.Add(peak);
                }
            }

            var peakQualityList = new List <ChromPeakQualityData>();

            //iterate over peaks within tolerance and score each peak according to MSFeature quality
#if DEBUG
            var tempMinScanWithinTol = (int)resultList.Run.NetAlignmentInfo.GetScanForNet(normalizedElutionTime - Parameters.NETTolerance);
            var tempMaxScanWithinTol = (int)resultList.Run.NetAlignmentInfo.GetScanForNet(normalizedElutionTime + Parameters.NETTolerance);
            var tempCenterTol        = (int)resultList.Run.NetAlignmentInfo.GetScanForNet(normalizedElutionTime);


            Console.WriteLine("SmartPeakSelector --> NETTolerance= " + Parameters.NETTolerance + ";  chromMinCenterMax= " + tempMinScanWithinTol + "\t" + tempCenterTol + "" +
                              "\t" + tempMaxScanWithinTol);
            Console.WriteLine("MT= " + currentResult.Target.ID + ";z= " + currentResult.Target.ChargeState + "; mz= " + currentResult.Target.MZ.ToString("0.000") + ";  ------------------------- PeaksWithinTol = " + peaksWithinTol.Count);
#endif

            currentResult.NumChromPeaksWithinTolerance = peaksWithinTol.Count;
            currentResult.NumQualityChromPeaks         = -1;

            ChromPeak bestChromPeak;
            if (currentResult.NumChromPeaksWithinTolerance > _parameters.NumChromPeaksAllowed)
            {
                bestChromPeak = null;
            }
            else
            {
                foreach (var chromPeak in peaksWithinTol)
                {
                    var pq = new ChromPeakQualityData(chromPeak);
                    peakQualityList.Add(pq);

                    // TODO: Currently hard-coded to sum only 1 scan
                    resultList.Run.CurrentScanSet = ChromPeakUtilities.GetLCScanSetForChromPeakUIMF(chromPeak, resultList.Run, 1);

                    //This resets the flags and the scores on a given result
                    currentResult.ResetResult();

                    //generate a mass spectrum
                    msgen.Execute(resultList);

                    //find isotopic profile
                    TargetedMSFeatureFinder.Execute(resultList);

                    //get fit score
                    fitScoreCalc.Execute(resultList);

                    //get i_score
                    resultValidator.Execute(resultList);

                    //collect the results together
                    AddScoresToPeakQualityData(pq, currentResult);

#if DEBUG
                    pq.Display();
#endif
                }

                //run a algorithm that decides, based on fit score mostly.
                bestChromPeak = determineBestChromPeak(peakQualityList, currentResult);
            }

            currentResult.ChromPeakQualityList = peakQualityList;

            resultList.Run.CurrentScanSet = ChromPeakUtilities.GetLCScanSetForChromPeakUIMF(bestChromPeak, resultList.Run, Parameters.NumScansToSum);

            UpdateResultWithChromPeakAndLCScanInfo(currentResult, bestChromPeak);
        }
        public override void Execute(ResultCollection resultList)
        {
            Check.Require(resultList.Run.CurrentMassTag != null, this.Name + " failed. MassTag was not defined.");

            var currentResult = resultList.GetTargetedResult(resultList.Run.CurrentMassTag);

            if (msgen == null)
            {
                msgen = MSGeneratorFactory.CreateMSGenerator(resultList.Run.MSFileType);
                msgen.IsTICRequested = false;
            }

            var mt = resultList.Run.CurrentMassTag;

            float normalizedElutionTime;

            if (currentResult.Run.CurrentMassTag.ElutionTimeUnit == DeconTools.Backend.Globals.ElutionTimeUnit.ScanNum)
            {
                normalizedElutionTime = resultList.Run.CurrentMassTag.ScanLCTarget / (float)currentResult.Run.GetNumMSScans();
            }
            else
            {
                normalizedElutionTime = resultList.Run.CurrentMassTag.NormalizedElutionTime;
            }

            //collect Chrom peaks that fall within the NET tolerance
            var peaksWithinTol = new List <ChromPeak>(); //

            foreach (ChromPeak peak in resultList.Run.PeakList)
            {
                if (Math.Abs(peak.NETValue - normalizedElutionTime) <= Parameters.NETTolerance)     //peak.NETValue was determined by the ChromPeakDetector or a future ChromAligner Task
                {
                    peaksWithinTol.Add(peak);
                }
            }

            var peakQualityList = new List <ChromPeakQualityData>();

            //iterate over peaks within tolerance and score each peak according to MSFeature quality

            var tempMinScanWithinTol = (int)resultList.Run.NetAlignmentInfo.GetScanForNet(normalizedElutionTime - Parameters.NETTolerance);
            var tempMaxScanWithinTol = (int)resultList.Run.NetAlignmentInfo.GetScanForNet(normalizedElutionTime + Parameters.NETTolerance);
            var tempCenterTol        = (int)resultList.Run.NetAlignmentInfo.GetScanForNet(normalizedElutionTime);

            IqLogger.Log.Debug("SmartPeakSelector --> NETTolerance= " + Parameters.NETTolerance + ";  chromMinCenterMax= " + tempMinScanWithinTol + "\t" + tempCenterTol + "" +
                               "\t" + tempMaxScanWithinTol);
            IqLogger.Log.Debug("MT= " + currentResult.Target.ID + ";z= " + currentResult.Target.ChargeState + "; mz= " + currentResult.Target.MZ.ToString("0.000") + ";  ------------------------- PeaksWithinTol = " + peaksWithinTol.Count);

            currentResult.NumChromPeaksWithinTolerance = peaksWithinTol.Count;
            currentResult.NumQualityChromPeaks         = -1;

            ChromPeak bestChromPeak;

            if (currentResult.NumChromPeaksWithinTolerance > _parameters.NumChromPeaksAllowed)
            {
                bestChromPeak = null;
            }
            else
            {
                foreach (var chromPeak in peaksWithinTol)
                {
                    var pq = new ChromPeakQualityData(chromPeak);
                    peakQualityList.Add(pq);

                    var lcscanSet = ChromPeakUtilities.GetLCScanSetForChromPeak(chromPeak, resultList.Run, _parameters.NumMSSummedInSmartSelector);
                    resultList.Run.CurrentScanSet = lcscanSet;

                    //This resets the flags and the scores on a given result
                    currentResult.ResetResult();

                    //generate a mass spectrum
                    msgen.Execute(resultList);

                    //find isotopic profile
                    TargetedMSFeatureFinder.Execute(resultList);

                    try
                    {
                        //get fit score
                        fitScoreCalc.Execute(resultList);

                        //get i_score
                        resultValidator.Execute(resultList);
                    }
                    catch (Exception)
                    {
                        currentResult.FailedResult = true;
                    }

                    //collect the results together



                    AddScoresToPeakQualityData(pq, currentResult);
#if DEBUG
                    IqLogger.Log.Debug(pq.Display() + Environment.NewLine);
#endif
                }

                //run a algorithm that decides, based on fit score mostly.
                bestChromPeak = determineBestChromPeak(peakQualityList, currentResult);
            }

            currentResult.ChromPeakQualityList = peakQualityList;

            if (Parameters.SummingMode == SummingModeEnum.SUMMINGMODE_STATIC)
            {
                resultList.Run.CurrentScanSet = ChromPeakUtilities.GetLCScanSetForChromPeak(bestChromPeak, resultList.Run, Parameters.NumScansToSum);
            }
            else
            {
                resultList.Run.CurrentScanSet = ChromPeakUtilities.GetLCScanSetForChromPeakBasedOnPeakWidth(bestChromPeak, resultList.Run,
                                                                                                            Parameters.AreaOfPeakToSumInDynamicSumming, Parameters.MaxScansSummedInDynamicSumming);
            }

            UpdateResultWithChromPeakAndLCScanInfo(currentResult, bestChromPeak);
        }